- Discrete Output Type: transistor
- Range Of Product: Modicon M221
- Discrete Output Number: 8 transistor 2 fast output
- Product Or Component Type: logic controller
- Discrete Output Current: 0.5 A
- Discrete Output Voltage: 24 V DC
- Analogue Input Number: 2 0…10 V
- [Us] Rated Supply Voltage: 24 V DC
- Discrete Input Number: 8 , discrete input 4 fast input IEC 61131-2 Type 1
Complementary
- Discrete Input Logic: sink or source (positive/negative)
- Data Backed Up: 256 kB built-in flash memory backup of application and data
- Exct Time For Event Task: 60 s response time
- Input Impedance: 100 kOhm analog input || 3.4 kOhm input || 4.9 kOhm fast input
- Electrical Connection: terminal block, 3 for connecting the 24 V DC power supply || connector, 4 for analogue inputs || mini B USB 2.0 connector for a programming terminal || removable screw terminal block, 10 for inputs || removable screw terminal block, 11 for outputs
- Maximum Cable Distance Between Devices: shielded cable <10 m fast input || unshielded cable <30 m output || unshielded cable <30 m digital input || unshielded cable <1 m analog input || shielded cable <3 m fast output
- Height: 90 mm
- Discrete Output Logic: positive logic (source)
- Discrete Input Voltage: 24 V
- Maximum Power Consumption In W: 22 W 24 V with max number of I/O expansion module) || 3.2 W 24 V without I/O expansion module)
- Inrush Current: 35 A
- Discrete Input Voltage Type: DC
- Communication Service: Modbus master || Modbus slave
- Positioning Functions: PTO 2 pulse/direction 100 kHz) || PTO 1 CW/CCW 100 kHz)
- Maximum Current Per Output Common: 4 A
- Transmission Rate: 1.2…115.2 kbit/s (115.2 kbit/s by default) 15-15 m RS485 || 1.2…115.2 kbit/s (115.2 kbit/s by default) 3-3 m RS232 || 480 Mbit/s USB
- Clock Drift: <= 30 s/month 25-25 C
- Battery Type: BR2032 lithium non-rechargeable 4 year(s)
- Output Frequency: 100 kHz fast output (PWM/PLS mode) Q0…Q1 || 5 kHz output Q2…Q3 || 0.1 kHz output Q4…Q6
- Communication Port Protocol: USB port USB – SoMachine-Network || non isolated serial link Modbus master/slave – RTU/ASCII or SoMachine-Network
- Protection Type: short-circuit and overload protection with automatic reset || short-circuit protection on output || overload and short-circuit protection 1 A
- Marking: CE
- Backup Time: 1 year 25 C by interruption of power supply)
- Discrete I/O Number: 16
- Reset Time: 1 s automatic reset
- Regulation Loop: adjustable PID regulator up to 14 simultaneous loops
- Maximum Number Of I/O Expansion Module: 7 (local I/O-Architecture) || 14 (remote I/O-Architecture)
- Power Supply Output Current: 0.52-0.52 A 5 V expansion bus || 0.49-0.49 A 24 V expansion bus
- Net Weight: 0.264 kg
- Application Structure: 8 interrupt tasks || 1 cyclic auxiliary task || 1 configurable freewheeling/cyclic master task
- Voltage State 0 Guaranteed: <= 5 V input
- Maximum Voltage Drop: <1 V
- Configurable Filtering Time: 0 ms input || 3 ms input || 12 ms input
- Maximum Size Of Object Areas: 8000 %MW memory words || 255 %C counters || 512 %KW constant words || 255 %TM timers || 512 %M memory bits
- Memory Capacity: 256 kB user application and data RAM 10000 instructions || 256 kB internal variables RAM
- Conversion Time: 1 ms per channel + 1 controller cycle time analog input
- Voltage State 1 Guaranteed: >= 15 V input
- Function Available: frequency generator || PWM || PLS
- Control Signal Type: single phase || pulse/direction || A/B
- Supply Voltage Limits: 20.4-28.8 V
- Integrated Connection Type: USB port mini B USB 2.0 || non isolated serial link serial 1 RJ45 RS485 || non isolated serial link serial 2 RJ45 RS232/RS485
- Execution Time Per Instruction: 0.2 s Boolean
- Mechanical Durability: 20000000 cycles transistor output
- Absolute Accuracy Error: +/- 1 % of full scale analog input
- Mounting Support: top hat type TH35-15 rail IEC 60715 || top hat type TH35-7.5 rail IEC 60715 || plate or panel with fixing kit
- Local Signalling: for PWR 1 LED (green) || for RUN 1 LED (green) || for module error (ERR) 1 LED (red) || for SD card access (SD) 1 LED (green) || for BAT 1 LED (red) || for SL1 1 LED (green) || for SL2 1 LED (green) || for I/O state 1 LED per channel (green)
- Response Time: 35 s turn-off, I2…I5 input || 5 s turn-on, I0, I1, I6, I7 fast input || 35 s turn-on, other terminals input || 5 s turn-off, I0, I1, I6, I7 fast input || 100 s turn-off, other terminals input || 5 s turn-on, turn-off, Q0…Q1 output || 50 s turn-on, turn-off, Q2…Q3 output || 300 s turn-on, turn-off, other terminals output
- Discrete Input Current: 7 mA discrete input || 5 mA fast input
- Execution Time For 1 Kinstruction: 0.3 ms event and periodic task || 0.7 ms other instruction
- Analogue Input Resolution: 10 bits
- Realtime Clock: with
- Lsb Value: 10 mV
- Width: 70 mm
- Depth: 70 mm
- Maximum Tungsten Load: <12 W output and fast output
- Maximum Leakage Current: 0.1 mA transistor output
- Data Storage Equipment: 2 GB SD card optional)
- Insulation: between input and internal logic 500 V AC || between fast input and internal logic 500 V AC || non-insulated between inputs || between output and internal logic 500 V AC || between output groups 500 V AC || non-insulated between analogue input and internal logic || non-insulated between analogue inputs || between fast output and internal logic 500 V AC || non-insulated between outputs
- Supply: serial 1)serial link supply 5 V, <200 mA
- Counting Input Number: 4 fast input (HSC mode) 100 kHz 32 bits
- Permitted Overload On Inputs: +/- 30 V DC 5 min maximum)analog input || +/- 13 V DC permanent)analog input
Offer Sustainability
- Rohs Exemption Information: Yes
- Mercury Free: Yes
- Environmental Disclosure: ENVPEP1403012EN
- Sustainable Offer Status: Green Premium product
- Pvc Free: Yes
- Reach Regulation: Reference contains Substances of Very High Concern above the threshold
- California Proposition 65: WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
- Weee: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- China Rohs Regulation: X
- Circularity Profile: ENVEOLI1403012EN
- Eu Rohs Directive: Pro-active compliance (Product out of EU RoHS legal scope)
Environment
- Product Certifications: RCM || cULus || ABS || LR || IACS E10 || DNV-GL || EAC || CSA
- Resistance To Conducted Disturbances: 10 V 0.15…80 MHz EN/IEC 61000-4-6 || 3 V 0.1…80 MHz Marine specification (LR, ABS, DNV, GL) || 10 V spot frequency (2, 3, 4, 6.2, 8.2, 12.6, 16.5, 18.8, 22, 25 MHz) Marine specification (LR, ABS, DNV, GL)
- Resistance To Electromagnetic Fields: 10 V/m 80 MHz…1 GHz EN/IEC 61000-4-3 || 3 V/m 1.4 GHz…2 GHz EN/IEC 61000-4-3 || 1 V/m 2…2.7 GHz EN/IEC 61000-4-3
- Standards: EN/IEC 61010-2-201 || EN/IEC 60664-1 || EN/IEC 61131-2
- Immunity To Microbreaks: 10 ms
- Storage Altitude: 0-3000 m
- Pollution Degree: <= 2
- Ambient Air Temperature For Operation: -10-55 C horizontal installation) || -10-35 C vertical installation)
- Shock Resistance: 147 m/s 11 ms
- Resistance To Magnetic Fields: 30 A/m 50/60 Hz EN/IEC 61000-4-8
- Vibration Resistance: 3.5 mm 5-8.4 Hz symmetrical rail || 3.5 mm 5-8.4 Hz panel mounting || 1 gn 8.4-150 Hz symmetrical rail || 1 gn 8.4-150 Hz panel mounting
- Ambient Air Temperature For Storage: -25-70 C
- Environmental Characteristic: ordinary and hazardous location
- Relative Humidity: 10-95 %, without condensation in operation) || 10-95 %, without condensation in storage)
- Ip Degree Of Protection: IP20 with protective cover in place
- Resistance To Electrostatic Discharge: 8 kV in air EN/IEC 61000-4-2 || 4 kV on contact EN/IEC 61000-4-2
- Surge Withstand: 2 kV power lines (AC) common mode EN/IEC 61000-4-5 || 2 kV relay output common mode EN/IEC 61000-4-5 || 1 kV I/O common mode EN/IEC 61000-4-5 || 1 kV shielded cable common mode EN/IEC 61000-4-5 || 0.5 kV power lines (DC) differential mode EN/IEC 61000-4-5 || 1 kV power lines (AC) differential mode EN/IEC 61000-4-5 || 1 kV relay output differential mode EN/IEC 61000-4-5 || 0.5 kV power lines (DC) common mode EN/IEC 61000-4-5
- Resistance To Fast Transients: 2 kV EN/IEC 61000-4-4 power lines) || 2 kV EN/IEC 61000-4-4 relay output) || 1 kV EN/IEC 61000-4-4 I/O) || 1 kV EN/IEC 61000-4-4 Ethernet line) || 1 kV EN/IEC 61000-4-4 serial link)
- Operating Altitude: 0…6561.68 ft (0…2000 m)
- Electromagnetic Emission: conducted emissions 79 dBV/m QP/66 dBV/m AV power lines (AC))0.15-0.5 MHz EN/IEC 55011 || conducted emissions 73 dBV/m QP/60 dBV/m AV power lines (AC))0.5-300 MHz EN/IEC 55011 || conducted emissions 120…69 dBV/m QP power lines)10-150 kHz EN/IEC 55011 || conducted emissions 63 dBV/m QP power lines)1.5-30 MHz EN/IEC 55011 || radiated emissions 40 dBV/m QP class A 10 m)30-230 MHz EN/IEC 55011 || conducted emissions 79…63 dBV/m QP power lines)150-1500 kHz EN/IEC 55011 || radiated emissions 47 dBV/m QP class A 10 m)200-1000 MHz EN/IEC 55011
Downloads
Spec Sheet
CAD
CONTROLLER M221-16/24IO Modular- 3D CAD – MCADID0000727_2D-right (dwg)
CONTROLLER M221-16/24IO Modular- 3D CAD – MCADID0000727_2D-top (dwg)
CONTROLLER M221-16/24IO Modular- 3D CAD – MCADID0000727_2D-bottom (dwg)
CONTROLLER M221-16/24IO Modular- 3D CAD – MCADID0000727 (pdf)
CONTROLLER M221-16/24IO Modular- 3D CAD – MCADID0000727_2D-back (dwg)
CONTROLLER M221-16/24IO Modular- 3D CAD – MCADID0000727_2D-bottom (dxf)
CONTROLLER M221-16/24IO Modular- 3D CAD – MCADID0000727_2D-right (dxf)
CONTROLLER M221-16/24IO Modular- 3D CAD – MCADID0000727_2D-left (dwg)
CONTROLLER M221-16/24IO Modular- 3D CAD – MCADID0000727_3D-simplified (stp)
CONTROLLER M221-16/24IO Modular- 3D CAD – MCADID0000727_2D-top (dxf)
CONTROLLER M221-16/24IO Modular- 3D CAD – MCADID0000727_2D-back (dxf)
CONTROLLER M221-16/24IO Modular- 3D CAD – MCADID0000727_2D-front (dwg)
CONTROLLER M221-16/24IO Modular- 3D CAD – MCADID0000727_2D-left (dxf)
CONTROLLER M221-16/24IO Modular- 3D CAD – MCADID0000727_2D-isometric (dxf)
CONTROLLER M221-16/24IO Modular- 3D CAD – MCADID0000727_2D-isometric (dwg)
CONTROLLER M221-16/24IO Modular- 3D CAD – MCADID0000727_2D-front (dxf)
Catalog
Discover catalog for Modicon M221 Programmable logic controller for hardwired architectures – Catalog+Modicon+M221+Programmable+logic+controller_+February+2023 (pdf)
Discover Catalog EcoStruxure Machine Expert-Basic Programming software for Modicon M221 logic controller – Catalog+EcoStruxure+Machine+ExpertBasic+Programming+software+for+Modicon+M221+logic+controller (pdf)
Automation and Control Essentials Catalog 2023-EN – DIA5ED2170101EN_v7_Web (pdf)
User guide
Modicon M221 Logic Controller, Hardware Guide – SoMachine Basic – EIO0000001384.06 (pdf)
Modicon M221 Logic Controller, Hardware Guide – M221_Hardware_EN_EIO0000003313_02 (pdf)
Modicon M221 Logic Controller, User Guide – M221_UserGuide_EN_EIO0000000976.03 (pdf)
Certificate
Modicon, TM221, IACS, DNV, Marine – DNV_GL_Cert.No._TAA00000VM_valid_202510 (pdf)
Modicon, TM221, TM3, IACS, ABS, Marine – ABS_Cert.No._18-YO-1808013-PDA_valid_20231226 (pdf)
Modicon, M2xx, Certificate, cULus, Ordinary Location – NRAQ.E316433+-+Programmable+Controllers (pdf)
Modicon, TM221, Certificate, CSA, Ordinary Location – CSA_2684938_Certificate_M221_TM3 (pdf)
Modicon, TM221, TM3, Certificate, cULus, Hazardous Location – NRAG.E361380+-+Programma…+in+Hazardous+Locations (pdf)
Modicon, TM2xx, Certificate, cULus, Hazardous Location – NRAG.E361380+-+Programmable+Controllers+for+Use+in+Hazardous+Locations (pdf)
Declaration of conformity
Modicon DoC TM221 – NHA4191001.04_DeclarationOfConformity_TM221_signed (pdf)
RCM_SupplierDeclarationOfConformity_TM221_TM3 – RCM_SupplierDeclarationOfConformity_TM221_TM3 (pdf)
Circularity Profile
Modicon M221 Bricks controllers, Product End-of-Life Instructions – ENVEOLI1403012EN_V3 (pdf)
Instruction sheet
TM221M… Logic Controller – Instruction sheet (EN) – HRB59602_09 (pdf)
Environmental Disclosure
Modicon M221 Bricks controllers, Product Environmental Profile – ENVPEP1403012EN_V3 (pdf)
Videos
Establishing Modbus RTU Communication Between M221 and HMIS5T | Schneider Electric Support Measuring Memory Consumption on M221 with SoMachine Basic | Schneider Electric Support Making On-Line Changes to Modicon M221 with SoMachine Basic | Schneider Electric Support Setting Clock on Modicon M221 Controller in SoMachine | Schneider Electric Support How to perform a firmware upgrade on the M221 | Schneider Electric Support Setting Persistent Variables with the M221 in SoMachine Basic | Schneider Electric Support