Specifications
- Range Compatibility: TeSys (TeSys T) LTMR motor controller
- Supply: via the controller
- Product Or Component Type: extension module
- Product Name: TeSys T
- Range: TeSys
- Device Application: equipment monitoring and control
- Device Short Name: LTME
Contractual warranty
Complementary
- Contacts Type And Composition: without
- Height: 61 mm
- Connection Pitch: 5.08 mm
- Pollution Degree: 3
- Logic Input Number: 4
- Maximum Operating Rate: 1800 cyc/h
- Connections – Terminals: control circuit connector 1 0.25-2.5 mm AWG 24…AWG 14)flexible with cable end || control circuit connector 1 0.2-2.5 mm AWG 24…AWG 14)flexible without cable end || control circuit connector 1 0.25-2.5 mm AWG 24…AWG 14)flexible without cable end || control circuit connector 1 0.2-2.5 mm AWG 24…AWG 14)solid without cable end || control circuit connector 2 0.2-1 mm AWG 24…AWG 14)flexible with cable end || control circuit connector 2 0.2-1.5 mm AWG 24…AWG 14)flexible without cable end || control circuit connector 2 0.5-1.5 mm AWG 24…AWG 14)flexible without cable end || control circuit connector 2 0.2-1 mm AWG 24…AWG 14)solid without cable end
- Input Current: 7 mA
- Current State 1 Guaranteed: logic input < 15 V 2…15 mA 15 ms
- Net Weight: 0.21 kg
- [Uimp] Rated Impulse Withstand Voltage: 6 kV current or voltage measurement circuit EN/IEC 60947-4-1 || 0.8 kV supply, inputs and outputs EN/IEC 60947-4-1
- Electromagnetic Compatibility: electrostatic discharge, 3, 8 kV air, 6 kV contact, conforming to EN/IEC 61000-4-2 || fast transients immunity test (other circuits), level 3, 2 kV, conforming to EN/IEC 61000-4-4 || fast transients immunity test (on supply and relay outputs), level 4, 4 kV, conforming to EN/IEC 61000-4-4 || conducted RF disturbances, 10 V, conforming to EN/IEC 61000-4-6 || control circuit: surges (common mode), 1 kV, conforming to EN/IEC 61000-4-5 || control circuit: surges (serial mode), 1 kV, conforming to EN/IEC 61000-4-5 || communication: surges (common mode), 2 kV, conforming to EN/IEC 61000-4-5 || voltage inputs: surges (serial mode), 2 kV, conforming to EN/IEC 61000-4-5 || voltage inputs: surges (common mode), 4 kV, conforming to EN/IEC 61000-4-5
- Measurement Accuracy: 1 % voltage 100…830 V) || 3 % power factor || 5 % active and reactive power
- Current State 0 Guaranteed: logic input < 5 V <= 15 mA 5 ms
- [Ui] Rated Insulation Voltage: 690 V EN/IEC 60947-1 || 690 V CSA C22.2 No 14 || 690 V UL 508
- Compatibility Code: LTME
- Width: 45 mm
- Tightening Torque: control circuit 0.5-0.6 N.m flat 3 mm
- Overvoltage Category: III
- Depth: 120.7 mm
- Maximum Operating Frequency: 2 Hz
- Metering Type: voltage U21, U32, U13, V1, V2, V3 || imbalance voltage || frequency || calculated active and reactive energy (+/- W.h, +/- VAR.h) || reactive power Q, Q1, Q2, Q3 || power factor || active power P, P1, P2, P3
Offer Sustainability
- Rohs Exemption Information: Yes
- Mercury Free: Yes
- Environmental Disclosure: ENVPEP060308EN_V2
- Sustainable Offer Status: Green Premium product
- Pvc Free: Yes
- Reach Regulation: Reference contains Substances of Very High Concern above the threshold
- Weee: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- China Rohs Regulation: Product out of China RoHS scope. Substance declaration for your information.
- Circularity Profile: ENVEOLI100411EN_V2
- Eu Rohs Directive: Compliant
- Halogen Content Performance: Halogen free plastic parts product
Environment
- Product Certifications: UL || NOM || ATEX || BV || CSA || EAC || RINA || LROS (Lloyds register of shipping) || DNV || ABS || GL || KERI || RMRoS || C-tick || CCC
- Mechanical Robustness: shocks half sine wave acceleration15 Gn for 11 ms EN/IEC 60068-2-27 || vibrations mounted on symmetrical rail1 Gn, 5…300 Hz EN/IEC 60068-2-6 || vibrations plate mounted4 Gn, 5…300 Hz EN/IEC 60068-2-6
- Ambient Air Temperature For Operation: -20-60 C
- Standards: IEC 60947-4-1 || UL 508 || EN 60947-4-1 || IACS E10 || CSA C22.2 No 14
- Ambient Air Temperature For Storage: -40-80 C
- Protective Treatment: 12 x 24 hour cycles EN/IEC 60068-2-30 || 48 h EN/IEC 60070-2-11 || TH EN/IEC 60068
- Operating Altitude: <= 6561.68 ft (2000 m) without derating
- Fire Resistance: 650 C EN/IEC 60695-2-12 || 960 C UL 94
- Ip Degree Of Protection: IP20
Downloads
Spec Sheet
User guide
TeSys T LTMR Motor Management Controller Installation Guide – DOCA0128EN-02 (pdf)
TeSys T – Use in Explosive Atmospheres – 1672602-06 (pdf)
CAD
TeSys T – Extention 4E control tension – 3D CAD – MCADPD0004693_2D-isometric (dwg)
TeSys T – Extention 4E control tension – 3D CAD – MCADPD0004693_2D-left (dwg)
TeSys T – Extention 4E control tension – 3D CAD – MCADPD0004693_2D-bottom (dwg)
TeSys T – Extention 4E control tension – 3D CAD – MCADPD0004693_2D-top (dwg)
TeSys T – Extention 4E control tension – 3D CAD – MCADPD0004693_3D-simplified (stp)
TeSys T – Extention 4E control tension – 3D CAD – MCADPD0004693_2D-isometric (dxf)
TeSys T – Extention 4E control tension – 3D CAD – MCADPD0004693_2D-back (dwg)
TeSys T – Extention 4E control tension – 3D CAD – MCADPD0004693_2D-front (dwg)
TeSys T – Extention 4E control tension – 3D CAD – MCADPD0004693_2D-top (dxf)
TeSys T – Extention 4E control tension – 3D CAD – MCADPD0004693_2D-right (dwg)
TeSys T – Extention 4E control tension – 3D CAD – MCADPD0004693 (pdf)
TeSys T – Extention 4E control tension – 3D CAD – MCADPD0004693_2D-right (dxf)
TeSys T – Extention 4E control tension – 3D CAD – MCADPD0004693_2D-bottom (dxf)
TeSys T – Extention 4E control tension – 3D CAD – MCADPD0004693_2D-back (dxf)
TeSys T – Extention 4E control tension – 3D CAD – MCADPD0004693_2D-left (dxf)
TeSys T – Extention 4E control tension – 3D CAD – MCADPD0004693_2D-front (dxf)
Certificate
TeSys T, Certificate, IEC/CEI, DNV – DNV+e-12838+TESYS+T_Marine+Certificate (pdf)
CB Certificate TeSys T, LTMR/LTMEV, made in China, according to IEC 60947-4-1 Ed3 – TeSysT-LTMR-LTMEV_FR659184@ (pdf)
Catalog
Digest Catalog 16: NEMA and Definite Purpose Contactors and Starters (SEP 2022) – 0100CT1901_SEC-16_SEP2022 (pdf)
TeSys catalogue – 2020 – chapter C1 Motor management systems TeSys LUTM, T – C1+-+Motor+management+systems_EN+(web) (pdf)
Circularity Profile
End-of-Life Instructions TeSys T – ENVEOLI100411EN_V2 (pdf)
Environmental Disclosure
Motor management system – ENVPEP060308EN_V02.01-EN (pdf)
Instruction sheet
LTM E – LTM R expansion module – Instruction sheet – AAV7950501-06 (pdf)
Declaration of conformity
EU_Declaration_SC16040410D_TeSys_LTMR-LTMEV-LTM9F – M_EU_declaration_of_conformity_SC16040410D (pdf)
Videos
Replacing AC Coil on a TeSys D Series Contactor | Schneider Electric Support Disabling Network Connectivity on TeSys T Motor Management System | Schneider Electric Support Resetting a LTMR TeSys T Module Back to Factory Defaults Locally | Schneider Electric Support Replacing DC Coil on a TeSys D Series Contactor | Schneider Electric Support Configuring IP Address for TeSys T Controller in SoMove | Schneider Electric Support Connecting TeSys T Controller to SoMove via Modbus Serial | Schneider Electric Support Resetting TeSys T Normally Closed Contacts by Exiting Config Mode | Schneider Electric Support Switching from Modbus TCP to IP Communication on TeSys T Controllers | Schneider Electric Support