standard analog input kit STB – 2 I – 15 bits + sign

(0 Reviews)
$412.92 $123.876

Specifications Range Of Product: Modicon STB distributed I/O solution Type Of Filter: single low pass input filter 25 Hz Product Or Component Type: standard analog input kit Analogue Input Number: 2 Analogue Input Resolution: 15 bits + sign Kit Composition:...

Specifications

  • Range Of Product: Modicon STB distributed I/O solution
  • Type Of Filter: single low pass input filter 25 Hz
  • Product Or Component Type: standard analog input kit
  • Analogue Input Number: 2
  • Analogue Input Resolution: 15 bits + sign
  • Kit Composition: STBART0200 module || STBXTS1100, 6-terminal screw type connector || STBXBA1000 base || STBXTS2100, 6-terminal spring clamp connector
  • Analogue Input Type: voltage +/- 80 mV || thermocouple -200…+760 C thermocouple J || thermocouple -270…+1000 C thermocouple E || thermocouple -270…+1370 C thermocouple K || thermocouple -270…+400 C thermocouple T || thermocouple -50…+1665 C thermocouple R || thermocouple -50…+1665 C thermocouple S || temperature probe -100…+260 C Cu 10 2, 3 or 4 wires IEC || temperature probe -100…+450 C Pt 100 2, 3 or 4 wires US/JIS || temperature probe -100…+450 C Pt 1000 2, 3 or 4 wires US/JIS || temperature probe -200…+850 C Pt 100 2, 3 or 4 wires IEC || temperature probe -200…+850 C Pt 1000 2, 3 or 4 wires IEC || temperature probe -60…+180 C Ni 100 2, 3 or 4 wires IEC || temperature probe -60…+180 C Ni 1000 2, 3 or 4 wires IEC || thermocouple +130…+1820 C thermocouple B

Contractual warranty

  • Warranty: 18 months

Complementary

  • Insulation Between Channels And Logic Bus: 1500 V for 1 minute
  • Cold Swapping: yes
  • Maximum Supply Current For Sensors: 100 mA per input channels
  • Input Impedance: 10 MOhm +/- 80 mV
  • Status Led: 1 LED (Green) module status (RDY) || 1 LED (Red) module error (ERR)
  • Hot Swapping Fallback: yes for standard NIMs
  • Supply: power distribution module
  • Data Format: EN 61131-2 || IEC 61131-2
  • Current Consumption: 30 mA 5 V DC logic bus
  • Marking: CE
  • Fallback Status: state 0 basic NIMs || user configurable standard NIMs
  • Conversion Time: 150 ms voltage 60 Hz || 400 ms thermocouple with external cold-junction compensation 50 Hz || 170 ms voltage 50 Hz || 180 ms temperature probe 60 Hz 2 or 4 wires || 200 ms temperature probe 50 Hz 2 or 4 wires || 210 ms thermocouple with internal cold-junction compensation 60 Hz || 230 ms thermocouple with internal cold-junction compensation 50 Hz || 300 ms temperature probe 60 Hz 3 wires || 340 ms temperature probe 50 Hz 3 wires || 360 ms thermocouple with external cold-junction compensation 60 Hz
  • Addressing Requirement: 1 word for cold-junction compensation || 2 input words
  • Absolute Accuracy Error: +/- 0.1 % of full scale 25 C internal || +/- 0.15 % of full scale 25 C external
  • Maximum Wiring Resistance: 20 Ohm Cu 10 IEC/US/JIS 2 or 3 wires || 500 Ohm Pt 1000 IEC/US/JIS 4 wires || 20 Ohm Ni 100 IEC/US/JIS 2 or 3 wires || 20 Ohm Pt 100 IEC/US/JIS 2 or 3 wires || 200 Ohm Ni 1000 IEC/US/JIS 2 or 3 wires || 200 Ohm Pt 1000 IEC/US/JIS 2 or 3 wires || 50 Ohm Cu 10 IEC/US/JIS 4 wires || 50 Ohm Ni 100 IEC/US/JIS 4 wires || 50 Ohm Pt 100 IEC/US/JIS 4 wires || 500 Ohm Ni 1000 IEC/US/JIS 4 wires
  • Absolute Maximum Input: +/- 7.5 V DC
  • Protection Type: short-circuit protection
  • Overvoltage Category: II
  • Product Compatibility: mounting base STBXBA1000 || power distribution module STBPDT3100/3105
  • [Us] Rated Supply Voltage: 24 V DC
  • Measurement Accuracy: +/- 1 C Ni 100 25 C external || +/- 1.75 C thermocouple K with external cold-junction compensation 25 C || +/- 1.75 C thermocouple R with external cold-junction compensation 25 C || +/- 1.75 C thermocouple S with external cold-junction compensation 25 C || +/- 1.75 C thermocouple T with external cold-junction compensation 25 C || +/- 2 C Pt 100 25 C external || +/- 2 C Pt 1000 25 C external || +/- 2.85 C thermocouple B with external cold-junction compensation 60 C || +/- 2.85 C thermocouple E with external cold-junction compensation 60 C || +/- 2.85 C thermocouple J with external cold-junction compensation 60 C || +/- 2.85 C thermocouple K with external cold-junction compensation 60 C || +/- 1 C Ni 100 25 C internal || +/- 2.85 C thermocouple R with external cold-junction compensation 60 C || +/- 2.85 C thermocouple S with external cold-junction compensation 60 C || +/- 2.85 C thermocouple T with external cold-junction compensation 60 C || +/- 3.6 C thermocouple R with internal cold-junction compensation 25 C || +/- 4 C Cu 10 25 C external || +/- 4 C Cu 10 25 C internal || +/- 4 C thermocouple K with internal cold-junction compensation 25 C || +/- 4.1 C thermocouple S with internal cold-junction compensation 25 C || +/- 4.2 C thermocouple R with internal cold-junction compensation 60 C || +/- 4.4 C thermocouple T with internal cold-junction compensation 25 C || +/- 1 C Ni 1000 25 C external || +/- 4.6 C thermocouple B with internal cold-junction compensation 25 C || +/- 4.6 C thermocouple E with internal cold-junction compensation 25 C || +/- 5 C thermocouple S with internal cold-junction compensation 60 C || +/- 5.1 C thermocouple J with internal cold-junction compensation 25 C || +/- 5.5 C thermocouple K with internal cold-junction compensation 60 C || +/- 6.4 C thermocouple T with internal cold-junction compensation 60 C || +/- 6.8 C thermocouple B with internal cold-junction compensation 60 C || +/- 6.8 C thermocouple E with internal cold-junction compensation 60 C || +/- 7 C thermocouple J with internal cold-junction compensation 60 C || +/- 1 C Ni 1000 25 C internal || +/- 1 C Pt 100 25 C internal || +/- 1 C Pt 1000 25 C internal || +/- 1.75 C thermocouple B with external cold-junction compensation 25 C || +/- 1.75 C thermocouple E with external cold-junction compensation 25 C || +/- 1.75 C thermocouple J with external cold-junction compensation 25 C
  • Measurement Resolution: 0.01 mV voltage || 0.1 C or 0.1 F temperature probe || 0.1 C or 0.1 F thermocouple

Offer Sustainability

  • Rohs Exemption Information: Yes
  • Mercury Free: Yes
  • Environmental Disclosure: ENVPEP1511012EN
  • Sustainable Offer Status: Green Premium product
  • Reach Regulation: Reference contains Substances of Very High Concern above the threshold
  • California Proposition 65: WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Weee: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
  • China Rohs Regulation: X
  • Circularity Profile: ENVEOLI1511012EN
  • Eu Rohs Directive: Pro-active compliance (Product out of EU RoHS legal scope)

Environment

  • Product Certifications: UL || FM Class 1 Division 2 || CSA || ATEX Cat 3G || C-tick
  • Ambient Air Temperature For Storage: -40…185 F without derating
  • Ambient Air Temperature For Operation: 0-70 C
  • Shock Resistance: 30 gn 11 ms IEC 88 reference 2-27
  • Vibration Resistance: +/-0.35 mm 10-58 Hz || 3 gn 58-150 Hz 35 x 7.5 mm symmetrical DIN rail || 5 gn 58-150 Hz 35 x 15 mm symmetrical DIN rail
  • Ip Degree Of Protection: IP20 conforming to EN 61131-2 class 1
  • Pollution Degree: 2 IEC 60664-1
  • Ambient Air Temperature For Storage: -40-85 C without derating
  • Relative Humidity: 95-95 % 60-60 C without condensation
  • Operating Altitude: <= 6561.68 ft (2000 m)
  • Ambient Air Temperature For Operation: 32…140 F without derating

Downloads

Spec Sheet

CAD

Module on base 13,9 mm – 3D CAD – MCADID0005033_2D-bottom (dwg)
Module on base 13,9 mm – STB-IO4_CAD2D_all.dwf
Module on base 13,9 mm – 3D CAD – MCADID0005033_2D-back (dwg)
Module on base 13,9 mm – STB-IO4_CAD2D_all (dwg)
Module on base 13,9 mm – 3D CAD – MCADID0005033_3D-simplified (stp)
Module on base 13,9 mm – 3D CAD – MCADID0005033_2D-left (dxf)
Module on base 13,9 mm – 3D CAD – MCADID0005033_2D-top (dwg)
Module on base 13,9 mm – 3D CAD – MCADID0005033_2D-back (dxf)
Module on base 13,9 mm – 3D CAD – MCADID0005033_2D-bottom (dxf)
Module on base 13,9 mm – STB-IO4_CAD2D_all (pdf)
Module on base 13,9 mm – STB-IO4_CAD2D_all.wmf
Module on base 13,9 mm – 3D CAD – MCADID0005033_2D-right (dwg)
Module on base 13,9 mm – 3D CAD – MCADID0005033_2D-front (dxf)
Module on base 13,9 mm – 3D CAD – MCADID0005033_2D-right (dxf)
Module on base 13,9 mm – 3D CAD – MCADID0005033_2D-left (dwg)
Module on base 13,9 mm – 3D CAD – MCADID0005033_2D-isometric (dxf)
Module on base 13,9 mm – 3D CAD – MCADID0005033_2D-top (dxf)
Module on base 13,9 mm – 3D CAD – MCADID0005033_2D-front (dwg)
Module on base 13,9 mm – STB-IO4_CAD2D_all (dxf)
Module on base 13,9 mm – 3D CAD – MCADID0005033_2D-isometric (dwg)

Declaration of conformity

Modicon STB, Declaration of Conformity, UKCA, Schneider Electric – UK_DoC_STB_May2022.docx (pdf)
DCC_STB_JUL2016 – DCC_STB_JUL2016 (pdf)
ACMA_RCM_STB_FEB2015 – ACMA_RCM_STB_FEB2015 (pdf)

Certificate

Modicon STB, Certificate, IACS, ABS, Marine – Certificate+No.23-2343675-PDA+signed (pdf)
EAC_RUCFRME83B00132_STB – EAC_RUCFRME83B00132_STB_JUL2014 (pdf)
Modicon STB, Certificate, CSA, Ordinary Location – CSA_225844_2591645_STB_AUG2017 (pdf)
Modicon, Certificate, UL, Ordinary Location – UL_E486184_NRAQ7_ALL_Jan2023 (pdf)
Modicon STB, Certificate, cCSAus, Hazardous Location – HazLoc_cCSAus_225844_700136731_STB_NOV2017 (pdf)
Modicon, Certificate, UL, Ordinary Location – UL_E486184_NRAQ_ALL_Jan2023 (pdf)
Modicon STB, Certificate, IACS, DNV-GL, Marine – DNV-GL_TAA0000064_STB_JAN21 (pdf)

Catalog

Catalogue: IP 20 distributedinputs/outputsModicon STB (LR PDF) – MKTED2130401EN+(web) (pdf)

Circularity Profile

Modicon STB IP20 distrbuted inputs/outputs and power modules, Product End-of-Life Instructions – ENVEOLI1511012EN_V1 (pdf)

Environmental Disclosure

Modicon STB IP20 distrbuted inputs/outputs and power modules, Product Environmental Profile – ENVPEP1511012EN_V1 (pdf)

There are no reviews yet.